LX2 Button & Indicator Overview

  • Updated

The LaserPecker LX2 is equipped with a Multifunction Button and an Annular Indicator Light.

image.png

The indicator provides real-time feedback on the machine’s operating status through different colors and light states. By pressing the button in various states, you can easily perform different functions.

The table below summarizes the indicator color, device status, and the actions triggered by a short press or long press of the button.

BuzzerAnnular IndicatorMachine StatusButton Operation
/Blinking WhiteStandby/
/Blinking BlueNetwork Configured, Not Connected to Software/
/Solid BlueStandby, Connected to Software/
/Blinking WhiteAuto-FocusingLong Press to Exit
/Blinking WhiteMeasuring Curved SurfaceLong Press to Exit
/Blinking WhiteMaterial PositioningShort Press to Mark; Long Press to Exit
/Solid PurplePreviewingLong Press to Exit
/Solid GreenReady to StartShort Press to Start; Long Press to Cancel
Beeps onceSolid GreenBooting/
Beeps onceBlinking WhiteConfiguring NetworkLong Press Button for 5s to Enter Network Configuration Mode
Beeps onceBreathing RGBProcessingShort Press to Pause; Long Press to Cancel
Beeps onceBlinking Red & BlueFirmware Upgrading/
Beeps onceBlinking PurpleProcessing PausedShort Press to Resume; Long Press to Stop
Beeps onceBlinking PurpleDevice Error (Machine Tilted During Engraving)/
Beeps three timesBlinking RedFirmware Startup FailedReboot After Power Off for 3 Seconds
Continuous beepBlinking YellowLaser Module Not Properly Connected / Lid Not Fully Closed/
Continuous beepBlinking RedFlame DetectedShort Press to Cancel Alarm

Was this article helpful?

1 out of 2 found this helpful